- Testing Equipment[10]
- Other Analysis Instruments[1]
- Other Measuring & Analysing Instruments[6]
- Gas Generation Equipment[2]
- Industrial Air Conditioners[1]
- Laboratory Thermostatic Devices[2]
- Other Machinery[3]
- Temperature Instruments[2]
- Densitometers[5]
- Concentration Meters[2]
- Other Pressure Measuring Instruments[1]
- Measuring & Analysing Instrument Stocks[1]
- Contact Person : Ms. Li Kate
- Company Name : Liaoning Huake Petroleum Apparatus Science & Technology Co., Ltd.
- Tel : 86-24-23468791
- Fax : 86-24-23468790
- Address : Liaoning,Shenyang,No. 57 Nanwu Road, Heping district, Shenyang, Liaoning,China
- Country/Region : China
- Zip : 110005
A80 Gas chromatograph
The functions:
Built-in touch screen industrial PCMulti-detector for selectionSplit system with micro-packed columnVacuum negative pressures for ample injectionAutomatic selection module of many sample flow pathsDesign of Explosion-proof armor heatingIntegration module design with multi-column and multi-valve Sweep protection and leak-tightness automatic sample injection diaphragm valve
A80 Main technical Parameter
Structural composition
Column box:4 separated electrical heating Column box, working temperature:ambient~350°C Temperature controlling precision: ±0.1°C
Detector: TCD, FID, HID, ECD, PID. working temperature: ambient~350°C
Sampling/ Column cut valve: membrane valve, rolling piston valve, High temperature high Pressure valve, blow through valve Corrosion resistant valve
Chromatographic column: 1/16 1/8packed column, capillary column
EFC: Though max 9 access EFC
Performance
Measuring scope: TCD: 5ppm~100%, FID: 0.1ppm~100%, HID: ppb~100ppm,
ECD: 0.01ppt~10ppm, PID: 0.1ppb~1000ppm
Repeatability: ±3%RSD
Analytical period: 5 seconds~3hours
Communication function
LAN TCP:/IP Agreement port open
USB2.0
RS232
Gas sampling requirements
Sample flow: 10~100ml/min
Sample filter: 2μ
Min pressure: 3~5psi lower pressure can be chosen
Max pressure: 75psi Higher pressure can be chosen
Highest sample temperature standard: 100°C, higher temperature can be chosen
Sampling tube material: Teflon tube, Stainless steel tube, polyimide tube Other materials can be chosen
Standardization
Mode: manual or automatic
Null point: automatic baseline revise
Measuring scope: steel cylinder Regulator
Quickly on-site logging analysis
One machine with double functions: 25 sec isolates C1~C5, 115 sec isolates C1~C8
All intelligent control, automatic ignition, automatic null point Calibration, automatic fault diagnosis
Measuring scope: component 5*10 -6-100%, total hydrocarbon: 10-5-100%
Natural chromatographic analysis
Separation for many valves and columns, TCD system analysis H2, O2, CH4, CO, C2H6, CO2, H2S, C2H4, C3H8, C3H6, C4, C5, C6+ and ect.
Analytical process
The analytical system consists of a ten connection valve, two 6-way valve, four Chromatographic column and one thermal conductivity detector.
The flow diagram lies in original state, when put the sample into No. 9 mouth of valve V1 into quantitative tube 1, after sweeping clean, switch V1 from OFF to ON, carrier gas 1 takes sample into analytical column DC200, before components flowing out, switch valve 1 from OFF to ON, C6+ was flow back to TCD, examined.
Components O2, N2, CH4, CO, CO2 and C2 flow out from DC200 and flow into chromatographic column PQ, and when components H2S, C3 and above have not flowed out, switch the valve V2 from OFF to ON. Then H2S, C3 and above will be brought into detector TCD by gas carrier 2 and be detected, switch the valve V2 from ON to OFF. Before CO2 and C2 flowing out, O2, N2, CH4, CO flow into chromatographic column 13X, switch the valve V3 from OFF to ON. Components CO2 and C2 will be detected by TCD in sequence. Switch the valve V3 from ON to OFF, components O2, N2, CH4 and CO will be detected. Analysis process finish.
A80 Gas chromatograph